| Physical Properties | Test Method | Unit | TypicalValue | ||||
| Density, 23℃ | ASTM D1505 | g/cm³ | 1.15 | ||||
| Tensile Strength | ASTM D638 | MPa | 12 | ||||
| Elongation at Break | ASTM D638 | % | 220 | ||||
| After Oven Aging, 168hrs at 136℃ |
ASTM D638 | ||||||
| Tensile Strength Retention | % | ≥85 | |||||
| Elongation at Break Retention | % | ≥85 | |||||
| Hot Set Test, 200°℃, 0.2MPa, 15min |
IEC540 | ||||||
| Elongation under Loading | % | 40 | |||||
| Permanent Deformation after Cooling | % | 6 | |||||
| Moisture Content | Kar Fisher | ppm | 450 | ||||
| Brittleness Temperature | ASTM D746 | ℃ | .45 | ||||
| Electrical Properties | |||||||
| DC Volume Resistivity at | |||||||
| 20℃ | ASTM D991 | Ω.cm | 50 | ||||
| 90℃ | Ω.cm | 500 | |||||
1. Temperature Setting of Extruder
a
| Zone | 1# | 2# | 3# | 4# | Tube | Head | |
| Temp. (℃) | 75℃ | 85℃ | 95℃ | 105℃ | 105℃ | 105℃ | |
b
| Zone | 1# | 2# | 3# | 4# | Tube | Head | Feeding、Water Cooling、Screw | |
| Temp. (℃) | 70℃ | 85℃ | 95℃ | 105℃ | 105℃ | 105℃ | 65℃ | |
2. It's recommended to use stainless steel wire filter(20×40×20).
3. The above temperature setting are the most typical ones. With different extruder devices, it can be adjusted in terms of the practical situation after extrusion in use, combining with melting pressure and current, in order to achieve the best extrusion result.
HJ0602 meets the applicable requirements as below when processed using sound extrusion practices and testing procedures.
-AEIC CS 8
-ICEA S-94-649
-IEC 60502
HJ0602 is a easy strippable insulation shielding compound, the peel force≤20N/CM.
HJ0602 is a cross-linkable semi-conductive shielding compound, specially designed for strippable insulation shielding compound of extruded insulated power cables rated voltage up to 36KV.
It is suitable for dry vulcanization processing method at high temperature. It provides fine surface smoothnessnice extrusion flowabilty, good performance to prevent scorch and stable volume resistivity.